TESTING AND ADJUSTING E205 Service Code in Electrical System (Short-circuiting in 2-stage relief solenoid) E205 20-324 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in 2-stage relief solenoid (in governor • pump controller system) — E205 DWK0KB Failure content • Abnormal current flew to the 2-stage relief solenoid circuit, when power was supplied to the circuit. Response from controller • Power supply to the 2-stage relief solenoid circuit is switched OFF. • Even after the failure cause disappears of itself, the machine operation does not return to normalcy, unless the engine starting switch is once turned OFF.
Phenomenon occurring on machine • The one-touch power max. switch does not work. Relative information • Operation of the 2-stage relief solenoid (ON or OFF) can be checked in the monitoring function. (Code No. 023: Solenoid 1) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 2-stage relief solenoid defective (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
V06 (male) Resistance value Between and 20 – 60 Ω Between and grounding Above 1 MΩ 2 Assembled-type diode D03 defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. D03 (male) Resistance value Between and Above 1 MΩ 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness from C03 (female) to J06 to V06 (female) , or between wiring harness between C03 (female) and D03 (female) and grounding Resistance value Above 1 MΩ 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting. C03 Working mode Voltage Between and grounding Other than L mode Below 1 V L mode 20 – 30 V