TESTING AND ADJUSTING E233 Service Code in Electrical System (Disconnection in PC-EPC solenoid system) E233 20-356 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Disconnection in PC-EPC solenoid (in governor • pump controller system) E02 E233 DXA0KA Failure content • No current flows to the PC-EPC solenoid circuit. Response from controller • None in particular (The solenoid does not function as there is no current flowing to it) • When the failure cause disappears of itself, the current returns to normalcy. Phenomenon occurring on machine • As load to the pump increases, the engine rotation drops sharply and sometimes the engine stalls.
Relative information • Output to PC-EPC solenoid (ampere) can be confirmed in the monitor function. (Code No. 013: PC-EPC solenoid current) • If there is no abnormality with the solenoid or any of the wiring harnesses, the machine can be operated in a working mode equivalent to E mode by turning the emergency driving switch ON. (At that time the monitor panel continues to display Service Code No.
[E233], but this is not abnormal) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 PC-EPC solenoid defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. V21 (male) Resistance value Between and 7 – 14 Ω 2 Emergency pump driving switch defective (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
S21 Switch Resistance value Between and OFF Below 1 Ω ON Above 1 MΩ Between and OFF Below 1 Ω ON Above 1 MΩ 3 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) and S21 Resistance value Below 1 Ω Wiring harness between S21 and V21 (female) Resistance value Below 1 Ω Wiring harness between C03 (female) and S21 Resistance value Below 1 Ω Wiring harness between S21 and V21 (female) Resistance value Below 1 Ω 4 Short-circuiting of wiring harness (Contact with 24 V cir- cuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position during the troubleshooting.
Between wiring harness between C03 (female) and S21 and grounding Voltage Below 1 V Between wiring harness between S21 and V21 (female) and grounding Voltage Below 1 V 5 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. C03 (female) Resistance value Between and 7 – 14 Ω