Komatsu — Service Code in Electrical Equipment (Short-circuiting in attachment oil flow rate adjusting EPC)...

TESTING AND ADJUSTING E245 Service Code in Electrical Equipment (Short-circuiting in attachment oil flow rate adjusting EPC) (Multi-monitor only) E245 Electrical Circuit Diagram for Attachment Oil Flow Rate Adjusting EPC Solenoid in Governor • Pump Controller 20-360 PC210/240-7K User Code S ervice Code Failure Code Failure phenomenon Short-circuiting in attachment oil flow rate adjusting EPC (in governor • pump controller system) — E245 DXE4KB Failure content • Abnormal current flew to the attachment oil flow rate adjusting EPC solenoid circuit. • Response from • controller The controller reduces to zero (0) power to the attachment oil flow rate adjusting EPC solenoid circuit.

Even when the failure cause disappears, the EPC solenoid circuit does not return to normalcy, unless the engine starting switch is once turned OFF. Phenomenon occurring on • machine The attachments do not move. Relative • information It can be confirmed in the monitor function how power (ampere) is supplied to the attachment oil flow rate adjusting EPC solenoid circuit. (Code No. 017:

Service solenoid current) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting At ad 1 (In or ★ tachment oil flow rate justing EPC defective ternal short-circuiting grounding fault) Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. V30 (male) Resistance value Between and 7 – 14 Ω Between and grounding Above 1 MΩ Gr ha 2 (C cir ★ ounding fault of wiring rness ontact with grounding B cuit) V Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

etween wiring harness between C03 (female) and 30 (female) and grounding Resistance value Above 1 MΩ G 3 co ★ overnor • pump ntroller defective Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. C03 (female) Resistance value Between and 7 – 14 Ω Between and grounding Above 1 MΩ