TESTING AND ADJUSTING E256 Service Code in Electrical System (Incorrect nonvolatile memory data) E256 20-362 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Incorrect nonvolatile memory data (in governor • pump controller) — E256 DA20KT Failure content • The data in the nonvolatile memory in the controller cannot be updated. Response from controller • None in particular • Even if the failure cause disappears, the nonvolatile memory does not return to normalcy, unless the engine starting switch is once turned OFF. Phenomenon occurring on machine • In some cases control parameters of the machines change, resulting in increase or decrease of the ma- chine's power.
Relative information • Recorded in the nonvolatile memory are part of the machine control parameters Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Governor • pump controller defective As it is an internal failure, troubleshooting is impossible. (There is no problem with continuing with use of the controller, so long as no failure is visually evident)