Komatsu — Service Code in Electrical System (Short-circuiting in governor motor Phase A and Phase B)

TESTING AND ADJUSTING E318 Service Code in Electrical System (Short-circuiting in governor motor Phase A and Phase B) E318 20-374 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Disconnection in governor motor Phase A and Phase B (in governor • pump controller system) E05 E318 DY10KB Failure content • Abnormal current flew to the governor motor, when power is supplied to the motor. Response from controller • None in particular • If the failure cause disappears, the governor motor returns to normalcy. Phenomenon occurring on machine • The engine rotation cannot be controlled. • The engine rotation drops to low idling. • There is hunting in the rotation.

• The engine does not stop. Relative information • Operation of the governor motor (current) can be confirmed in the monitor function. (Code No. 033: Governor motor Phase A current, Code No. 034: Governor motor Phase B current) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Governor motor defec- tive (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

E11 (male) Resistance value Between and 2.5 – 7.5 Ω Between and 2.5 – 7.5 Ω Between and grounding Above 1 MΩ Between and grounding Above 1 MΩ 2 Disconnection of wiring harness (Disconnection or defec- tive contact with connec- tor) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between C03 (female) and E11 (female) and grounding Resistance value Above 1 MΩ Between wiring harness between C03 (female) and E11 (female) and grounding Resistance value Above 1 MΩ Between wiring harness between C03 (female) and E11 (female) and grounding Resistance value Above 1 MΩ Between wiring harness between C03 (female) and E11 (female) and grounding Resistance value Above 1 MΩ 3 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

C03 (female) Resistance value Between and 2.5 – 7.5 Ω Between and 2.5 – 7.5 Ω Between and grounding Above 1 MΩ Between and grounding Above 1 MΩ Between and grounding Above 1 MΩ Between and grounding Above 1 MΩ