Komatsu — E-1 Engine does not start (Engine does not rotate)

TESTING AND ADJUSTING E-1 E-1 Engine does not start (Engine does not rotate) PC210/240-7K 20-503 Failure information • The engine does not start (the engine does not rotate). Relative information • The following two engine start locking mechanisms are provided in the engine starting circuit. 1) Engine start locking by means of password in the monitor panel ( ) 2) Engine start locking by means of safety lock lever : The multi-monitor specification machine only. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Shortage in battery capacity Battery voltage Battery electrolyte specific gravity Above 24 V Above 1.26 2 Fuse Nos.

3 and 18 and Fusible Link A35 fault When a fuse or fusible link is blown, there is a big possibility that grounding fault occurred in the circuit. If a monitor lamp does not light up in the monitor panel, check the power source circuit between the battery and the specific fuse. 3 Engine starting switch fault (Internal disconnection) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

H15 (male) Position Resistance value Between and OFF Above 1 MΩ Start Below 1 Ω 4 Safety lock switch fault (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. S14 (female) Lock lever Resistance value Between and Release Below 1 Ω LOCK Above 1 MΩ 5 Engine starting motor cut relay, R11 and R13 defective (Internal disconnection or short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

R11 (female) & R13 (male) Resistance value Between and 100 – 500 Ω Between and Above 1 MΩ Between and Below 1 Ω 6 Engine starting motor fault (Internal disconnection or short-circuiting) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting. (If all of the power source, grounding (GND), generation signal and engine start input are normal and yet the engine start output is not normal, the engine start- ing motor relay is defective) Safety relay Engine start- ing switch Voltage Power source: Between B terminal and grounding Start 20 – 30 V GND (grounding): Between E terminal and grounding Connected Generation signal:

Between R terminal (A27 ) and grounding Below 1 V Engine start input: Between C terminal and grounding 20 – 30 V Engine start output: Between S terminal (A27 ) and grounding 20 – 30 V 7 Engine starting motor fault (Internal disconnec- tion or damage) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting. (If all of the power source, grounding (GND), generation signal and engine start input are normal and yet the engine start output is not normal, the engine start- ing motor relay is defective) Engine starting motor Engine start- ing switch Voltage Power source: B terminal and grounding Start 20 – 30 V Engine start input:

C terminal and grounding 20 – 30 V