Komatsu — Electrical Circuit Diagram for Fuel Dial

TESTING AND ADJUSTING E-2 E-2 Engine stops while in operation Electrical Circuit Diagram for Fuel Dial 20-506 PC210/240-7K Failure information • The engine suddenly stopped while in operation. Relative information • Input from the governor potentiometer (voltage) can be confirmed in the monitor function. (Code No. 031: governor potentiometer voltage) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting Gover 1 eter fa (Intern nor potentiom- ult al failure) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

E06 (male) Resistance value Between and 4.0 – 6.0 kΩ Between and 0.25 – 5.0 kΩ Between and 0.25 – 5.0 kΩ Disco ing ha 2 (Disco defect with c nnection of wir- rness nnection or ive contact onnector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between C01 (female) and E10 (female) Resistance value Below 1 Ω Groun wiring 3 (Cont groun ding fault of harness act with ding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness between C01 (female) and E10 (female) and grounding Resistance value Above 1 MΩ Gover 4 contro nor • pump ller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. C01 Voltage Between and 4.5 – 5.5 V Between and 0.5 – 4.5 V