TESTING AND ADJUSTING E-16 E-16 Fuel gauge does not display correctly Electrical Circuit Diagram for Fuel Level Sensor PC210/240-7K 20-523 Failure • information • Though fuel was refilled, the display does not exceed the red range (E). Though the remaining fuel level is low, the display does not drop below the green range (F). Relative • information Input from the fuel level sensor (voltage) can be confirmed in the monitor function. (Code No. 042:
Fuel sensor voltage) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Fuel level sensor fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. A60 (male) Fuel level Resistance value Between and grounding FULL (Upper limit) Approx. 12 Ω EMPTY (Lower limit) 85 – 110 Ω 2 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between P02 (female) and A60 (female) Resistance B value elow 1 Ω 3 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Between wiring harness between P02 (female) and A60 (female) and grounding Resistance Ab value ove 1 MΩ 4 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting.
Between wiring harness between P02 (female) and A60 (female) and grounding Voltage B elow 1 V 5 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. P01 Fuel level Resistance value Between and grounding FULL (Upper limit) Approx. 12 Ω EMPTY (Lower limit) 85 – 110 Ω