TESTING AND ADJUSTING E-25 E-25 "Bucket DIGGING" is not correctly displayed in monitor function Electrical Circuit Diagram for Bucket DIGGING PPC hydraulic Switch 20-534 PC210/240-7K Failure information • "Bucket DIGGING" is not correctly displayed in the monitor function (special function) on the monitor panel. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting Bucket D PPC hyd switch fa 1 (Internal tion and ing) IGGING raulic ult disconnec- short-circuit- ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting.
S01 (male) Bucket control lever Resistance value Between and NEUTRAL DIGGING Above 1 MΩ Below 1 Ω Disconne ing harne 2 (Disconn defective with conn ction of wir- ss ection or contact ector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness between C03 (female) and S01 (female) Resistance value Below 1 Ω Wiring harness between S01 (female) and grounding Resistance value Below 1 Ω Groundin wiring ha 3 (Contact groundin circuit) g fault of rness with g (GND) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Between wiring harness between C03 (female) and S01 (female) and grounding Resistance A value bove 1 MΩ Short-circ wiring ha 4 (Contact circuit) uiting of rness with 24 V ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. Between wiring harness between C03 (female) and S01 (female) and grounding Voltage Below 1 V Governor 5 controller • pump defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. C03 Bucket control lever Voltage Between and grounding NEUTRAL DIGGING 20 – 30 V Below 1 V