TESTING AND ADJUSTING E-27 E-27 "SWING" is not correctly displayed in monitor function 20-536 PC210/240-7K Failure information • "SWING" is not correctly displayed in the monitor function (special function) on the monitor panel. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Swing PPC hydraulic switch, left, fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting.
S03 (male) Swing control lever Resistance value Between and NEUTRAL Above 1 MΩ Left Below 1 Ω 2 Swing PPC hydraulic switch, right, fault (Internal disconnec- tion or short-circuit- ing) ★Turn the engine starting switch OFF for the preparations, and keep the engine running dur- ing the troubleshooting. S07 (male) Swing control lever Resistance value Between and NEUTRAL Above 1 MΩ Right Below 1 Ω 3 Disconnection of wir- ing harness (Disconnection or defective contact with connector) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) and S03 (female) , or wiring harness between C03 (female) and S07 (female) Resistance value Below 1 Ω Wiring harness between S03 (female) and grounding Resistance value Below 1 Ω Wiring harness between S07 (female) and grounding Resistance value Below 1 Ω 4 Grounding fault of wiring harness (Contact with grounding (GND) circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
Wiring harness between C03 (female) and S03 (female) , or wiring harness between C03 (female) and S07 (female) and grounding Resistance value Above 1 MΩ 5 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting. Wiring harness between C03 (female) and S03 (female) , or wiring harness between C03 (female) and S07 (female) and grounding Voltage Below 1 V 6 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position dur- ing the troubleshooting.
C03 Swing control lever Voltage Between and grounding NEUTRAL 20 – 30 V Right or left Below 1 V