TESTING AND ADJUSTING H-3, H-4 H-3 No work equipment, travel or swing move H-4 Abnormal noise is heard from around hydraulic pump PC210/240-7K 20-607 Failure information • No work equipment nor travel and swing functions can be set in motion. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of PPC lock solenoid valve ★Stop engine for preparations. Start troubleshooting at engine high idling.
Safety lock lever Main relief pressure Locked 0{0} Released 2.84 – 3.43 MPa {29 – 35kg/cm2} 2 Malfunctioning of self pressure decompression valve ★Stop engine for preparations. Start troubleshooting at engine high idling. Control lever Control circuit source pressure All control levers in NEUTRAL position 2.83 – 3.43 MPa {29 – 35kg/cm2} 3 Piston pump defective The piston pump is suspected of malfunctioning or an internal failure. Diagnose it in the following manner. • Remove the oil pressure measurement plug and crank the engine. If oil flows out, it is in normal condition. 4 Damper defective It is presumed that the pump shaft does not rotate due to some internal failure of the dumper.
Check the damper itself. Failure information • An abnormal noise is heard from around the hydraulic pump. Relative information — Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Hydraulic oil level lowered Make a visual check. 2 Quality of hydraulic oil bad Air may have get mixed with the oil. Make a visual check. 3 Hydraulic tank cap breather clogged It is presumed that the breather in the cap of hydraulic tanks is clogged, thereby causing negative pressure inside the tank. Make a visual check.
4 Hydraulic tank strainer clogged It is presumed that the strainer in the hydraulic tank is clogged, thereby causing negative pressure in the suction circuit. Make a visual check. 5 Piston pump defective The piston pump is suspected of an internal failure. Check the pump itself.