Komatsu — H-18 Machine swerves in travel

TESTING AND ADJUSTING H-18 H-18 Machine swerves in travel PC210/240-7K 20-615 Failure information • The machine tends to swerve while traveling. Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Malfunctioning of travel PPC valve ★Stop engine for preparations. Start troubleshooting at engine high idling.

Travel control lever PPC valve output pressure Forward or reverse Above 2.7 MPa {Above 28 kg/cm2} Differential output between right and left sides 0.4 MPa {4 kg/cm2} 2 Malfunctioning of self-pressure decompression valve ★Stop engine for preparations. Start troubleshooting at engine high idling. Control lever Control circuit source pressure All control levers in NEUTRAL 2.83 – 3.43 MPa {29 – 35 kg/cm2} 3 Improper adjustment or mal- functioning of LS valve ★Stop engine for preparations. Start troubleshooting at engine high idling.

Oil pressure to be measured Oil Pressure ratio All control levers in NEUTRAL Travel without load (control lever held at half stroke) Pump delivery pressure Nearly equal pressure 1 LS valve output pressure Approx. 3/5 4 Malfunctioning of travel inter- locking solenoid valve ★Stop engine for preparations. Start troubleshooting at engine high idling. Travel control lever PPC valve output pressure Operating one side only 0 {0} Operating both sides 2.84 – 3.43 MPa {29 – 35 kg/cm2} 5 Malfunctioning of travel inter- locking valve The travel interlocking valve is presumed to malfunction. Check the valve itself.

6 Malfunctioning of travel control valve (spool) The spool in the travel interlocking valve is presumed to malfunction. Check the spool itself. 7 Malfunction of travel motor ★Stop engine for preparations. Start troubleshooting at engine high idling. Travel control lever Amount of oil leakage from travel motor Travel relief 27.2 ¬/min 8 Final drive defective The final drive is suspected of an internal failure. Check the inside of the final drive directly. ★An internal failure in the final drive may well be determined by an abnormal noise from within, abnormal heat or metal chip or dust contained in the drained oil.