Komatsu — H-22 Track shoe does not turn (on one side only)

TESTING AND ADJUSTING H-22 H-22 Track shoe does not turn (on one side only) PC210/240-7K 20-619 Failure information • A track shoe does not turn (only on one side). Relative information • Set the working mode at A mode for the troubleshooting. Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Travel control valve (suction valve) seat defective The suction valve seat in the travel control valve is suspected of defect. Check the seat itself. 2 Travel motor (safety valve) seat defective The safety valve seat in the travel motor is suspected of defect. Check the seat itself.

3 Travel motor (check valve) seat defective The check valve seat in the travel motor is suspected of defect. Check the seat itself. 4 Travel Motor speed reduced ★Stop engine for preparations. Start troubleshooting at engine high idling. Travel control lever Amount of oil leakage from travel motor Travel relief 27.2 ¬/min 5 Final drive defective The final drive is suspected of an internal failure. Check the inside of the final drive directly. ★A failure inside the final drive may well be determined by an abnormal noise from within, abnormal heat generated or metal dust or chips contained in the drained oil.