Komatsu — ENGINE AND HYDRAULIC PUMP ASSEMBLIES

DISASSEMBLY AND ASSEMBLY ENGINE AND HYDRAULIC PUMP ASSEMBLIES 12 Refilling engine cooling water Refill engine cooling water through the water filler port up to the specified level. Engine cooling water: Approx. 22.8 l Refilling hydraulic oil (hydraulic tank) Refill hydraulic oil through oil filler port up to the specified level. Hydraulic tank: Approx. 240 l Let the water circulate to release any air pockets by starting the engine. Check the water level again. Circulate oil in the hydraulic system by starting the engine. Then check the oil level again. Air bleeding Refer to the Air Bleeding of Various Part section in the TESTING AND ADJUSTING chapter of this manual. PC210/240-7K 30-31