Hitachi Construction Machinery — Solenoid Valve Set Pressure

OPERATIONAL PERFORMANCE TEST / Component Test SOLENOID VALVE SET PRESSURE Preparation: 1. Stop the engine. 2. Push the air bleed valve on top of the hydraulic oil tank and release any remaining pressure. 3. Connect Dr. ZX and select the monitoring function. When Dr. ZX is not available, use the pressure gauge. Remove the line from the solenoid valve to be measured. Install tee (ST 6451), hose (Parts Number: 4216453), adapter (ST 6461) and pressure gauge (ST 6942). Solenoid Valve Pressure Gauge T157-05-04-002 Hose Adapter Tee : 17 mm, 19 mm, 22 mm 4. Start the engine. Confirm that no oil leakage is observed at the pressure gauge connection. 5.

Maintain the hydraulic oil temperature at 50 ± 5 ° C (122 ± 41 ° F). Measurement: 1. Measurement conditions are as below. 2. Operate as instructed below for each measuring solenoid valve: Solenoid Valve SG: Turn the power digging switch ON and OFF. Solenoid Valve SI: Turn the travel mode switch ON and OFF. Solenoid Valve SF: Combined operation of boom lower and arm, or boom lower and bucket. Solenoid Valve SC: Turn the boom mode selector switch ON. Operate the front and swing opera- tion. 3. Read the values on both Dr. ZX and the pressure gauge. 4. Repeat the measurement three times and calcu- late the average values. Evaluation: Refer to the Operational Performance Standard in Group T4-2.

SC SF SI SG T1V1-03-07-007 T4-5-4 Engine Control Dial Power Mode Switch Auto-Idle Switch Work Mode Fast Idle HP Mode OFF Digging Mode Slow Idle HP Mode OFF Digging Mode