OPERATIONAL PERFORMANCE TEST / Component Test Evaluation: 1. Convert the measured flow rates to those at the specified engine speed by using the following formulas: Qc = (Ns Ч Q) Ne Qc : Converted Flow Rate Q : Measured Flow Rate Ns : Specified Engine Speed (ZAXIS160LC- 3 : 2000 min -1 ) (ZAXIS180LC- 3 : 2000 min -1 ) Ne : Measured Engine Speed : Values indicated on Dr. ZX 2. Standard Flow Rate Refer to Operational Performance Standard in Group T4-2. NOTE: When actually measuring, install pipe (1 or 2) only to the pump to be measured.
5 4 3 1, 2 6 7 8 9 10 11 Delivery Hose (To Control Valve) T173-04-04-002 ZAXIS160LC- 3 ZAXIS180LC- 3 13 T1V1-04-05-002 1 - Pipe E (ST 6144) 5 - Hydraulic Tester (ST 6299) 8 - Test Hose (ST 6320) 11 - Bolt (ST 6409) (4 Used) 2 - Pipe B (ST 6143) 6 - Adapter PF1 Ч UNF1-7/8 (ST 6146) 9 - Flange (ST 6118) 12 - Plug 12 3 - Test Hose (ST 6145) 7 - Joint (ST 6330) 10 - Split Flange (ST 6130) 13 - Pipe 4 - Adapter PF1 Ч UNF1-7/8 (ST 6146) T4-5-19 13 12 T1T1