OPERATIONAL PERFORMANCE TEST / Standard ZAXIS160LC-3 OPERATIONAL PERFORMANCE STANDARD TABLE The standard Performance values are listed in the table below. Refer to the Group T4-3 to T4-5 for performance test procedures. Values indicated in parentheses are reference values. The following switch positions shall be selected and the hydraulic oil temperature shall be maintained as indicated below as the preconditions of performance tests unless otherwise instructed in each performance test procedure: Engine Control Dial : Fast Idle Power Mode Switch : P Mode Auto-Idle Switch: OFF Work Mode: Digging Mode Hydraulic Oil Temperature :
50 ± 5 ° C (122 ± 41 ° F) T4-2-1 PERFORMANCE TEST DESIGNATION ZAXIS160LC-3 (Performance Standard) Remarks Reference Page ENGINE SPEED min-1 T4-3-1 Slow Idle Speed 900±50 Lever in neutral Fast Idle Speed (With ECO deactivated) 2000±50 Fast Idle Speed 1900±50 Lever in neutral, Pilot shut-off lever: UNLOCK position Fast Idle Speed (Relief operation) 2000±50 Boom raise relief operation Fast Idle Speed (E mode) 1850±50 Lever in neutral Fast Idle Speed (HP mode) 2200±50 Relief operation of boom rasie and arm roll-in Auto-Idle Speed 1200±50 Warming-Up Speed 1400±100 ENGINE COMPRESSION PRESSURE MPa (kgf/cm2, psi) 3.04±0.2 (31±2, 442±29) Engine speed:
200min-1 T4-3-3 VALVE CLEARANCE (IN, EX) 0.15 With the engine cold T4-3-4 LUBRICANT CONSUMPTION (Rated output) mL/h 30 or less Hour meter: 2000 hours or less T4-3-7