CLAAS Rollant 240 / Rollant 250 — Module A22 - Uniwrap bale wrapper (Pin assignment on connector X100)

Electric System Rollant 240/250 TIC 24 rol-e-ze 11/04 Module A22 – Uniwrap bale wrapper (Pin assignment on connector X100) Pin Function Component Measuring variable Direction Circuit diagram no.

1 Not used - - - - 2 Rotate wrapping arm forward solenoid coil Y133 12 V PWM Output 21a 3 Not used - - - - 4 Wrapping arm basic position sensor B106 high- low (-) Input 21a 5 Film break monitoring receiver V12 high- low (-) Input 22a 6 Not used - - - - 7 Not used - - - - 8 Rollant circulation shut-off valve solenoid coil Y77-1 12 V Output 4c 9 Rotate wrapping arm backward solenoid coil Y134 12 V Output 21a 10 Lower tipping cradle solenoid coil Y135 12 V Output 19a 11 No function - - - 40c 12 Raise tipping cradle solenoid coil Y136 12 V Output 19a 13 Close film cutters solenoid coil Y140 12 V Output 22a 14 Raise wrapping table Y138 12 V Output 19a 15 Not used - - - - 16 Not used - - - - 17 Not used - - - - 18 Not used - - - - 19 Not used - - - - 20 Not used - - - - 21 Bale on wrapping table switch Z92 Earth Input 19a 22 Safety bracket switch Z91/91-2 Earth Input 21a 23 Wrapping arm rotations sensor B107 high- low (-) Input 21a 24 Not used - - - - 25 Not used - - - - 26 Not used - - - - 27 Not used - - - - 28 Lower wrapping table solenoid coil Y137 12 V Output 19a, 21a, 22a 29 0 Volt power (earth) A22 0 V Output 19a, 21a, 22a 30 Not used - - - - 31 12 V (sensor power supply) A22 12 V Output 19a 32 Not used - - - - 33 Not used - - - - 34 Wrapping table at top switch B105 high- low (-) Input 19a 35 Not used - - - - 36 Bale in tipping cradle sensor B102 high- low (-) Input 19a 37 Tipping cradle at bottom sensor B103 high- low (-) Input 19a 38 0 V (sensor power supply) A22 0 V Output 19a, 21a, 22a 39 Not used - - - - 40 Not used - - - - 41 Open film cutters Y139 12 V Output 22a 42 Not used - - - -