12. When replacing unit injectors, the control unit must be programmed with the new injector's trim codes. The code is printed on top of the unit injector electrical connector. The programming is performed using VCADS/TT and is necessary to ensure that engine timing and emission levels are correct. 333 Valve Yoke (Bridge) Installation [213 NV] Used yokes have established wear patterns. Yokes being returned to service must be installed in the same cylinder location from which they were removed. 1. Lubricate the tip of a valve stem with a small drop of clean engine oil. 2. Lubricate the yoke sockets with a small drop of clean engine oil in each one.
334 Figure 333 — Injector Trim Codes Due to the Engine Electronic Control Unit (EECU) self learning capability, it is necessary to reset learned EECU parameters after servicing some engine-related components. This allows the EECU to learn the new component's behavior. After servicing is complete, perform the “Learned Data Reset” located in VCADS/TT. Figure 334 — Installing the Inlet Valve Yoke 3. Set the yokes on their respective valve stems. If reinstalling an injector into the same location, reprogramming is not required. 13. Repeat the installation steps for the remaining unit injectors. Page 208 REPAIR INSTRUCTIONS, PART 1 1. Inlet Valve Stems 2. Valve Yoke