94 Install the AFI as marked at disassembly. 92 Figure 94 — Connecting AFI Check Valve Assembly 7. Install the P-clamp and screws to secure the AFI harness and fuel supply line to the diffuser. Figure 92 — AFI Installation 8. Fill the engine cooling system with the recommended coolant using the coolant extractor. 3. Secure the injector mounting bolts. Tighten the bolts according to specification. 4. Reconnect the aftertreatment fuel injector wiring harness connector. Secure the injector wiring harness with clips and tie straps. 9. Install all previously removed cables to the ground (negative) battery terminals. 10. Perform Aftertreatment Injector Adaptive Factor Reset using VCADS/Tech Tool.
5. Reconnect the coolant lines to the aftertreatment injector fittings and tighten to specification. 93 11. Start the engine, check for leaks and proper operation. After shutdown, replenish fluids as necessary. CLEANING 1. Apply the parking brake and place the shift lever in neutral. 2. Disconnect all cables from ground (negative) battery terminals to prevent personal injury from electrical shock. 3. Remove P-clamp screws securing the AFI harness and fuel supply line. 4. Disconnect the aftertreatment fuel injector double check valve assembly (CVA). Collect any residual fuel that might be in the fuel line in a suitable container. Figure 93 — AFI Coolant Line Connections 6.
Connect the aftertreatment fuel injector fuel check valve assembly (CVA) and tighten to specification. Page 88 MAINTENANCE