Yanmar 6D170E — OIL PUMP RELIEF VALVE, PISTON COOLING VALVE AND OIL COOLER BY-PASS VALVE

MAINTENANCE STANDARD LUBRICATION OIL PUMP RELIEF VALVE, PISTON OIL COOLER BY-PASS VALVE COOLING 6162F415 6162F416 VALVE SYSTEM AND 6162F417 Unit: No. Check item Criteria Remedy Standard size 1 Main relief valve spring Repair limit Free length Installed length} Installed toad 73.77 72.0 2.37 kg Regulator valve spring 21.5 17.6 2.97 kg 3s | [ton cooling valve spring test | 10282 | 7.1 4 Oil cooler by-pass valve spring 75.0 72.0 5 Main relief valve operating pressure Standard: Regulator valve operating pressure Standard: 2 6 mm Free length | Instalied load Replace 6.0 kg 3.3 + 0.3 kg/cm? . 8.0 + 0.8 kg/cm 2 Repair or replace 7 P iston cooling valve operating 1 I pressure Standard:

8 Oil cooler by-pass valve operating pressure Standard: . 170-1 SERIES . +. 3 1.3| kg/em? spring 4.5 + 0.5 kg/cm 2 14-19