OPERATOR’S STATION LOADER CONTROL LEVER 2 1 C Finger Type Is used to operate the lift arm and/or bucket. Lift Arm Control Lever (1) (C) Float: The lift arm free falls and can be moved as loads are applied. E 1 B N N D A (B) Lift arm Lower G F (N) Hold: The lift arm is stopped and held in that position. (A) Lift arm Raise (F) Detent: The lift arm is held in the rasised position M4GB-01-043 Bucket Control Lever (2) (E) Bucket Dump: The bucket is tilted forward to dump the bucket load. C E B (N) Hold: The bucket is stopped and held in that position. (D) Bucket Tilt: The bucket is tilted back, taking the transpor- tation attitude. N N (G) Detent:
When the bucket control lever is moved from the bucket dump position to the bucket tilt position, the bucket control lever is maintained in this position. D A M4GB-01-072 NOTE: • When lift arm control lever (1) is pulled further from the RAISE position (A), the lever is held in that posi- tion (F). Then, as soon as the lift arm is raised up to the position set by the arm kick out system, the arm is automatically returned to the HOLD position (N). • After dumping the bucket, when bucket control lever (2) is pulled further from the TILT position (D), the lever is held in that position (G).
Then, as soon as the bucket is tilted up to the position set by the bucket auto-leveler, the bucket is automatically returned to the HOLD position (N). M4GB-01-073 1-48