Doosan P086TI — Doosan P086TI Diesel Engine Operation & Maintenance Manual PDF (EN)

0.24 mm 0.12 ~ 0.17 mm Replace Camshaft bearing Limit Standard the bushing if the measured value is beyond the specified limit. EAOM4063 zu] @ Run-out Support the camshaft and check for run-out on two V blocks using a dial indi- cator. Correct or replace the cam shatt if the amount of run-out is beyond the value indicating need for servicing. Standard Limit 0.05 mm 0.2 mm 9.2.5. Crankshaft 1) Inspection of crankshaft (1) Defect check ik @ By naked eyes, check for any scratch or damage on the crankshaft journal and crank pin. @ By means color of magnetic check, check the particle test and crankshaft for any crack and if found, replace it.

(2) Wear zi] @ measuring With an outside the diameter micrometer of the measure crankshaft journals and pins in the directions as shown, and compare the measured values to determine the amount of wear. - 88 -