Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual (EN)

Engine Monitoring and Protection 15.1.7.2 Fuel Pressure Monitoring Configuration One parameter can be configured in Cat ET to customize the monitoring system for high fuel pressure monitoring. The ECU action level is the only programmable setting for fuel pressure monitoring. ECU warning level action defaults to “On” and can be configured to “On” or “Off.” The time delay and set point are defined by the factory and cannot be modified. The following table summarizes the configuration default settings and configuration ranges for all high fuel pressure monitoring configuration parameters: NOTE:

The engine must be running at engine speeds at or above low idle for 60 seconds before the above time delay is triggered. 15.1.7.3 Fuel Pressure Monitoring Installation No installation is required for fuel pressure monitoring to function. 15.1.8 Auxiliary Temperature 15.1.8.1 Auxiliary Temperature Monitoring Operation Auxiliary temperature is monitored to automatically protect a customer-defined system from exceeding the maximum temperature limit of that system. The auxiliary temperature measured by the ECU is compared to a maximum auxiliary temperature limit configured in the monitoring system for auxiliary temperature monitoring.

The maximum auxiliary temperature is checked for each ECU action level configured in the monitoring system. If the auxiliary temperature is above the maximum auxiliary temperature for the specified action level delay time, then the ECU takes the appropriate action to respond to the fault condition. Once the fault is detected, the ECU illuminates the warning and diagnostic lamps and logs the appropriate event code from the following table for the action taken: The ECU can respond to the high auxiliary temperature condition with any or all of the following actions: Warning, Derate, and Shutdown. The ECU logs an event code and illuminates the lamps for all action levels.

The ECU will respond with the following additional actions when the monitoring system is configured to Derate and Shutdown: • Derate: Engine power is reduced to 25 percent below rated power over 25 seconds (at a rate of one percent/second). • Shutdown: The engine will shut down immediately. I N D U S T R I A L E N G I N E E L E C T R O N I C S 102 HIGH FUEL PRESSURE MONITORING CONFIGURATION Action Default Value Time Delay (sec) Set Points Range Default Range Default Warning On None 8 758 kPa (gauge) Cat ET Description J1939 Description Status SPN FMI High Auxiliary Temperature Auxiliary Temperature #1 Warning 441 15 Derate 441 16 Shutdown 441 00