Engine Monitoring and Protection The ECU can respond to the high auxiliary pressure condition with any or all of the following actions: Warning, Derate, and Shutdown. The ECU logs an event code and illuminates the lamps for all action levels. The ECU will respond with the following additional actions when the monitoring system is configured to Derate and Shutdown: • Derate: Engine power is reduced to 25 percent below rated power over 25 seconds (at a rate of one percent/second). • Shutdown: The engine will shut down immediately.
15.1.9.2 Auxiliary Pressure Monitoring Configuration Three parameters can be configured in Cat ET to customize the monitoring system for high auxiliary pressure monitoring. 1. ECU action for an event code defaults to “On” for Warning and “Off” for Derate and Shutdown. All actions can be configured to “On” or “Off.” 2. Time delay to take action defaults to four seconds for Warning and three seconds for Derate and Shutdown. Time delay to take action can be set between one and 120 seconds. 3. Auxiliary pressure maximum limit default for all events is 1500 kPa. The maximum pressure limit for each action can be set within the range of 0 kPa and 3150 kPa.
The following table summarizes the configuration default settings and configuration ranges for high auxiliary pressure monitoring: NOTE: The engine must be running at engine speeds at or above low idle for 180 seconds before the above time delay is triggered. 15.1.9.3 Auxiliary Pressure Monitoring Installation Auxiliary pressure sensor is an optional attachment. Refer to Auxiliary Pressure Sensor in the Customer-Installed Components section of this document. 15.1.10 Altitude (Exhaust Temperature) 15.1.10.1 Altitude (Exhaust Temperature) Monitoring Operation Engine operation at higher altitudes can reduce engine performance because of limited air intake by the engine.
When air intake is limited, the fuel delivered to the engine needs to be reduced to minimize engine exhaust temperatures and thermal wear on the exhaust system and turbochargers. Engines with the A4 ECU have a new altitude derate strategy that reduces fuel quantity delivered to the engine based on a calculated percent exhaust temperature derate. The old altitude derate strategy was based on a calculated percent altitude derate. The old altitude derate strategy only used the measured atmospheric (barometric) pressure to calculate a percent altitude derate. The new altitude derate strategy uses a calculated exhaust temperature to calculate a percent exhaust temperature derate.
The exhaust temperature is calculated using measured atmospheric pressure, inlet air temperature, and engine speed. I N D U S T R I A L E N G I N E E L E C T R O N I C S 104 HIGH AUXILIARY PRESSURE MONITORING CONFIGURATION Action Default Value Time Delay (sec) Set Points Range Default Range Default Warning On 1 to 120s 4 0 kPa to 3150 kPa 1500 kPa Derate Off 1 to 120s 3 Shutdown Off 1 to 120s 3