Data Link Support 18 Data Link Support The Caterpillar industrial engines provide two data link connections on the engine ECU. OEM communication with the engine is via the CAN bus using SAE J1939 protocol. Caterpillar service tool communication with the engine is via the proprietary Caterpillar Data Link (CDL). Caterpillar recognizes that other CAN bus standards (higher level protocols) do exist and are used in off-highway applications, so the following sections provide some information for users of those standards. 18.1 SAE J1939 The SAE J1939 standard was initially developed for the U.S. truck and bus industry.

It has been expanded and is now the most widely used data link standard for industrial powertrains, with compliance from almost all engine manufacturers and most transmission manufacturers. 18.1.1 Summary of Key J1939 Application Issues This is a summary of key points and answers to frequently asked questions relating to design of a J1939 compatible network. It is intended to give a design overview and does not in any way replace or contradict the recommendations contained in the SAE J1939 standard documents. 18.1.1.1 Physical Layer • The data rate is 250 KBits/sec. • Twisted-pair cable, of a 120-Ohm impedance characteristic, should be used throughout.

Note that most commercially available twisted-pair cable is not suitable. • It is recommended that this cable is shielded (as per J1939-11) and that the screen is grounded at a central point in the network. Some machine manufacturers use unshielded twisted-pair cable (as per J1939-15), offering lower cost but lower immunity to electromagnetic noise. • The bus is linear and should be terminated with 120-Ohm resistors at either end. It is a common mistake to use one 60-Ohm resistor instead of two 120-Ohm resistors. This does not work correctly, however. • Maximum bus length is 40 m. • The terminating resistors should not be contained in network nodes.

• Network nodes are connected to the bus via stubs of the maximum recommended length of one meter. 18.1.1.2 Network Layer • J1939 recommends a bit sample point of 87 percent. This relatively late sample point gives best compromise for immunity to noise and propagation delay. This does restrict the size of the software jump width (SJW). • All nodes should have the same bit timing. • Accurate bit timing is essential (4єs +/- 0.2 percent). • It is recommended that the average bus load not be greater than 40 percent. I N D U S T R I A L E N G I N E E L E C T R O N I C S 124