Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual (EN)

Data Link Support Speed Control Mode — The engine control system will allow other modules to request engine speed for any length of time when operating in speed control mode. The TSC1 message will override any other engine speed demand, such as PWM throttle pedal input, to the engine speed governor. The transition from the hard wired speed demand input to CAN override speed demand is controlled by the engine speed governor and the rate of engine speed change is not limited by the engine acceleration rate limit configured via service tool.

The one exception to TSC1 message overriding any other speed control is that the Speed Limit Control is nonfunctional when the engine is configured to Torque Governing (refer to Section 13.2). The OEM can control the rate of engine speed change when initiating override by ramping the requested speed from the speed demand prior to initiating override (broadcast in EEC3 message) to the desired speed demand at a controlled rate of change. A similar process can be followed prior to relinquishing override control, but this is only possible if the speed demand input that will regain control is known (i.e. determine from accelerator pedal position broadcast in EEC2).

Speed Limit Mode — The engine control system will allow other modules to limit engine speed for any period of time when operating in speed limit mode. The TSC1 message sets the maximum limit for the speed demand input to the engine speed governor. The transition to or from the requested speed limit is controlled by the engine speed governor and the rate of engine speed change is not limited by the engine acceleration rate limit configured via the service tool.

The OEM can control the rate of engine speed change when initiating override by setting the requested speed limit to an engine speed greater than the speed demand prior to initiating override (broadcast in EEC3 message) and ramp the speed limit up or down at a controlled rate of change. Reverse process can be followed when removing the engine speed limit. Ramp the requested engine speed limit until the engine speed demand is no longer limited or speed demand limit is equal to high idle speed. Destination Address — The engine control system responds to the TSC1 message with destination address 00, but does not monitor the source address of the TSC1 message.

No restriction on the TSC1 message source has the following impact to the OEM: • Messages from modules with any source address are accepted (i.e. TSC1 messages do not necessarily have to be sent by the transmission). • The control system does not handle TSC1 messages differently based on message source. • The engine control system has no means to arbitrate between speed requests or limits from more than one source, thus the OEM must ensure that TSC1 messages are not sent from more than one source at a time as failure to do so may result in erratic engine operation.

The engine control system needs to differentiate between the end of a transmission by another controller and an intermittent failure. The engine control expects, therefore, that when a controller no longer wishes to demand engine speed it will terminate with at least one message with the control override bits set to 00. I N D U S T R I A L E N G I N E E L E C T R O N I C S 128