Data Link Support 18.1.2.6 Auxiliary Analog Information: PGN 65164 18.1.2.7 Electronic Engine Controller 3 (EEC3): PGN 65247 Engine Desired Operating Speed — Engine desired operating speed is the speed at which the engine would run if all load were removed and current speed demand conditions maintained. This is also the resulting arbitrated speed demand from all speed demand inputs and CAN override speed.
A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 133 Identifier Rate (msec) PGN Default Priority DP Source Destination 1C FE 8C 00 On req FE8C 7 0 00 — Send Receive Subgroup Name SPN Byte Bit Length State Units Resolution (unit/bit) Range Min Max X Auxiliary Temperature #1 441 1 8 °C 1 -40 210 Auxiliary Temperature #2 442 2 8 °C 1 -40 210 X Auxiliary Pressure #1 1387 3 8 kPa 16 0 4000 Auxiliary Pressure #2 1388 4 8 kPa 16 0 4000 Auxiliary Level 3087 5-6 16 mm 0.1 0 6425 Not Defined — 7-8 16 Identifier Rate (msec) PGN Default Priority DP Source Destination 18 FE DF 00 250 FEDF 6 0 00 — Send Receive Subgroup Name SPN Byte Bit Length State Units Resolution (unit/bit) Range Min Max X Nominal Friction — Percent Torque 514 1 1 8 % 1 -125 125 X Engine Desired Operating Speed 515 2-3 16 rpm 0.125 0 8031 Engine Desired Operating Speed Asymmetry Adjustment 519 4 8 ratio 1 0 250 Estimated Engine Parasitic Losses — Percent Torque 2978 5 8 % 1 -125 125 Not Defined — 6-8 24