Engine Speed Demand Two programmable parameters are provided in order for the ECU to interface with any PWM TPS. These two parameters are Throttle Input High Idle Duty Cycle and Throttle Input Low Idle Duty Cycle. • When the ECU receives a PWM signal from the TPS less than or equal to the programmed value for throttle input low idle duty cycle, the engine will govern speed at the programmed value for engine low idle. • When the ECU receives a PWM signal from the TPS greater than or equal to the programmed value for throttle input high idle duty cycle, the engine will go to full engine speed as dictated by Top Engine Limit (TEL) and high idle programmable parameters.

• The ECU will interpret throttle signals between a PWM duty cycle of 5 percent or less, or 95 percent or more, as invalid and consequently the engine will default to low idle and log a diagnostic code. This is referred to in the PWM throttle set-up diagram (Figure 5) as the upper and lower diagnostic zone. Figure 4: Throttle Position Sensor Parameter Diagram Minimum Throttle Position Throttle Input Low Idle Duty Cycle Set Point Throttle Input High Idle Duty Cycle Set Point Full Travel Distance of Throttle Maximum Throttle Position NOTE: The relationship of engine speed to PWM duty cycle may not be perfectly linear.

11.1.2 TPS Configuration Three parameters must be configured in Cat ET prior to using a PWM TPS. 1. TPS programmed to “installed” 2. Throttle Input Low Idle Duty Cycle defaults to 10, can be set from 10 to 40 percent (refer to PWM throttle set-up procedure below to determine proper settings) 3. Throttle Input High Idle Duty Cycle defaults to 90, can be set from 50 to 90 percent (refer to PWM throttle set-up procedure below to determine proper settings) NOTE: In previous models, engines used a parameter called desired speed input configuration. This parameter is no longer required. I N D U S T R I A L E N G I N E E L E C T R O N I C S 60