Engine Speed Demand 9X9591 PWM CONVERTER SET-UP PROCEDURE Step 1. Connect the 9X9591 PWM Converter to the engine according to the graphic in the 9X9591 PWM Converter Installation (Section 11.4.3). Connect Cat ET to the engine. Locate the “Throttle Input Duty Cycle” status parameter in the Cat ET status screens. This parameter is usually on screen 6, but the status screen number can vary depending upon engine model and Cat ET version. Note: The graphic in section 11.4.3 shows the usual configuration and the connections for the use of the D terminal are not shown.
However, the set-up procedure for the programmable configuration parameters is the same for applications using the external potentiometer and the S terminal as well as those using the internal potentiometer and the D terminal. Step 2. Adjust the potentiometer to the end of its range to produce the minimum duty cycle. This may cause a diagnostic code to log. Then adjust the potentiometer a known amount away from the end of the adjustment range. For example, for a 10-turn potentiometer, adjust one or two full turns away from the end of the range. Observe the “Throttle Input Duty Cycle” status parameter in Cat ET.
If the value is between 10 and 40 percent, this value can be used for the Throttle Input Low Idle Duty Cycle configuration parameter. This will allow the desired engine speed to reach low idle before the potentiometer reaches the end of its travel and helps to reduce the occurrences of diagnostic logging during adjustment. This also helps to provide a better relationship between the amount of adjustment of the potentiometer and the duty cycle since most potentiometers have better linearity away from the end of their adjustment range. Step 3. Adjust the potentiometer to end of its range to produce the maximum duty cycle. This may cause a diagnostic code to log.
Then adjust the potentiometer a known amount away from the end of the adjustment range. For example, for a 10-turn potentiometer, adjust one or two full turns away from the end of the range. Observe the “Throttle Input Duty Cycle” status parameter in Cat ET. If the value is between 50 and 90 percent, the value can be used for the Throttle Input High Idle Duty Cycle configuration parameter and will allow the desired engine speed to reach high idle before the potentiometer reaches the end of its travel. This also helps to reduce the occurrences of diagnostic logging during adjustment. Step 4. Enter the values for the two parameters into the configuration screen in Cat ET.
Clear the logged diagnostics created during this procedure. A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 67