Engine Speed Demand 11.6.2 J1939 Speed Control Configuration There is no configuration required in order to use J1939 speed control. Previous model engines used a parameter called desired speed input configuration. This parameter is no longer required. Refer to J1939 Section for more detail on the J1939 CAN TSC1 message. 11.6.3 J1939 Speed Control Installation If a customer requires engine control through the SAE J1939 data link, the data link wiring must be properly installed. See the Connectors and Wiring Harness Requirements section for proper data link installation information. 11.7 Power Take Off (PTO) Ramp Up/Down Mode NOTE:

PTO functions and intermediate speed switch will not work if torque control is selected in the engine primary governor mode. When the engine is operated in PTO mode, the full range governor functions in the same manner as described in section 13.1.1. 11.7.1 PTO Ramp Up/Down Mode Operation PTO ramp up/ramp down mode uses three switch to ground inputs to enable and control PTO speed demand setting. PTO ramp up/ramp down requires a PTO enable switch. This switch allows PTO ramp up/ramp down to be enabled or disabled. If the PTO enable switch is opened at any speed, the engine will immediately (not using engine accel.

rate) revert back to TPS signal or to low idle speed (if a TPS signal is not present). PTO ramp up/ramp down speed control allows for engine speed to be increased using a single pole, double throw, momentary switch (or a non-momentary type as well). If the switch is held in the ramp up position, the engine will accelerate toward full speed at the programmed engine accel. rate. If the switch is returned to the centered position at any time during the acceleration, engine speed will stabilize and govern at that speed. If the switch is held permanently in position, the engine will achieve and maintain full speed as per top engine limit and high idle parameters.

If the switch is held in the ramp down position, the engine will decelerate at the programmed engine accel. rate toward low idle speed. If the switch is returned to the centered position at any time during the deceleration, engine speed will stabilize and govern at that speed. PTO ramp up/ramp down will be overridden by intermediate engine speed or J1939 speed control. If PTO ramp up/ramp down and a TPS are used, then the ECU will choose the higher of the two speed signals. NOTE: Engine accel. rate is an rpm per second value and is used for both acceleration and deceleration for both intermediate engine speed and PTO functions. NOTE:

PTO strategy will latch the current speed setting if ramp up/ramp down inputs are selected at the same. This condition will remain until PTO enable switch is cycled. 11.7.2 PTO Ramp Up/Down Mode Configuration Two parameters must be configured in Cat ET prior to using PTO ramp up/down. 1. PTO Mode defaults to Ramp Up/Ramp Down. No change is required. 2. Engine Acceleration Rate defaults to 500 rpm per second. It can be set from 10 to 1000 rpm per second. Acceleration/deceleration rate should be considered prior to using this feature. This acceleration rate also applies in intermediate engine speed. I N D U S T R I A L E N G I N E E L E C T R O N I C S 70