Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual (EN)

Engine Speed Demand Typically, high idle speed is set less than or equal to 110 percent of TEL. It is important to consider that TEL and high idle (another programmable parameter) work together to determine the overrun* portion of the power curve. The overrun portion of the power curve will change as TEL and high idle are modified. The slope of the overrun curve will be determined by the difference between TEL and high idle. Refer to the Engine Governing section for more information on engine operation between TEL and high idle speed.

* Some other common terms for overrun are “run out” or “governor curve.” Engine Speed Limits Engine Power TEL Range High Idle Low Idle Range Maximum Rated Engine Speed Engine Speed (rpm) 11.12.2 High Idle Speed Configuration If the customer wants the engine’s high idle speed to be 10 percent greater than the high side of the top engine speed range, then no configuration is necessary. High idle speed will always default to be 10 percent greater than the high side of the top engine speed range. One parameter must be configured in Cat ET in order to program high idle speed. High idle speed must be programmed to meet two criteria:

• Equal to or greater than TEL • Less than or equal to 110 percent of the high side of the top engine speed range 11.12.3 High Idle Speed Installation No installation is necessary. I N D U S T R I A L E N G I N E E L E C T R O N I C S 76