Deutz — Fault table

7 Faults and remedies Fault table Faults Check valve clearance and set if necessary Check error according to error code and eliminate error if necessary 61 Check compression pressure Wrong SAE viscosity class of the engine lubricating oil Change the lubricating oil Cable connection to starter loose or oxidized Check cable connections Check injection line Engine does not start or is difficult to start Not disconnected (if possible) Check coupling Fuel tank empty Vent fuel system Cold starting device Check/replace Fuel quality does not comply with operating manual Change the fuel Battery defective or discharged Check battery Starter defective or pinion does not engage Check starter Check/replace Check/replace Check/replace Vent fuel system Faults Causes Measures Fuel suction pipe blocked Check Below starting limit temperature Check Check Faults Causes Measures Not disconnected (if possible) Check coupling Fuel tank empty Vent fuel system Fuel suction pipe blocked Check Below starting limit temperature Check Cold starting device Check/replace Wrong SAE viscosity class of the engine lubricating oil Change the lubricating oil Fuel quality does not comply with operating manual Change the fuel Battery defective or discharged Check battery Cable connection to starter loose or oxidized Check cable connections Starter defective or pinion does not engage Check starter Engine stop lever still in stop position Mechanical injection system Check/replace Stop magnet defective (release circuit) Check/replace Incorrect valve clearance Check valve clearance and set if necessary Air filter clogged / turbocharger defective Check/replace Air in fuel system Vent fuel system