Industrial — ServiSignal™ Mini Indicator

ENGINE remove and replace the air cleaner filter element. ServiSignal™Mini Indicator The two forward screws secure the cover to the base. The two rearmost screws provide the clamping force on the main support tube. NOTE The ServiSignal™Mini Indicator is installed on the air cleaner or air induction piping so it has access to clean filtered air. As the filter plugs and restriction increases, a red flag appears in the window. When it reaches the red zone, the air filter should be replaced. The indicator can be reset by pressing the button at the end of the indicator.

CAUTION To prevent possible engine damage, torque the four hex nuts attaching the air cleaner cover assembly to the body assembly to 8 Lb. ft. (10 N.m) after installing the new air cleaner fil- ter element. 5. After installation of the new filter element, rotate the main support tube forward and reinstall the upper stabilizer rod to its mounting bracket. 5 6. In any sequence, tighten the upper fasteners to a torque of 13 - 17 Lb. ft. (17 - 23 N.m). 1. Steps 1 and 6 2. Steps 2, 5, and 6 3. Steps 3 7 7. Tighten the two rearmost screws in the lower clamp to a torque of 4 - 4.5 Lb. ft. (5 - 6 N.m). 4. Rotate the main support tube rearward to provide clearance to (03/17) Y53-6077-1B1 5-109