Volume 1 of 3 - ENGINE WIRING SPECIFICATIONS AND RELATED MANUALS ¹ At room temperature unless otherwise noted. ¹ With increasing pressure the closed condition can be maintained up to 2800 kpa (405 psi), with decreasing pressure the closed condition can be maintained down to 170 kpa (25psi). І Contact position at the contacts of the harness connecto r. Resistor, Sender and Solenoid Specifications Part No. Component Description Resistance (Ohms)¹ 106-5122 Solenoid: A/CClutch 17.6±0.6 134-2540 Resistor: CANA 120 239-1134 Solenoid: Start Aid 20 Related Electrical Service Manuals Title Form Number Cross Reference for Electrical Connectors: REHS0970 Hydraulic Schematic: UENR0047 Alternator (95A):
197-8820 SENR4130 Alternator (150A): 249-0313 SENR4130 Starting Motor (STD): 338-3454 SENR3860 Starting Motor (ATCH): 237-1962 SENR3860 Engine Control: SENR9830 Off Machine Switch Specification Part No. Function Actuate Deactuate Contact Position 114-5333 A/C Refrigerant Pressure 275 to 1750 kPa¹ (39.9 to 253.8 psi) - - Normally Open²