Engine Tier-3 710655- Ch 1 page 26 SHOP MANUAL MT26-31 - 06.2005 CID Description Limits Typical Value Unit MT Value FCA1 PTO mode 1, accelrator pedal effective 0 - 1 1 0 = Active 1 = Not active FD11 PTO mode 4, max torque 0 - 5100 5100 rpm 5100 FE15 Low idle to adjust fuel adjustment.
Droop function on low idle 0 - 1 FCE3 Accelrator pedal value converted to reference engine speed 0 - 3200 array x 4 rpm 480/2500/ 2500/2500 FCF9 Accelrator break point for FCE3 0 - 100 array x 4 % 0/100/ 100/100 FCE5 Droop values for different accelrator pedal values 0 - 8 array x 4 rpm/ mg/st 4,5/4,5/ 4,0/0,5 FCFB Accelrator pedal breakpoint for FCE5 0 - 100 array x 4 % 0/20/80/ 100 FD77 Voltage breakpoints for 0% and 100% for redundant Accelrator pedal connected to input AUX AN on EMS _ 100 - 4900 Array x 2 485/2693 mV 485/2693 FD73 Engine speed dependent friction torque.
Breakpoints in flash, 500, 1000, 1500, 2200 rpm 0 - 5100 array x 4 Nm 0/0/0/0 FD75 FD71 Engine speed and temperature dependant friction torque. Breakpoints in flash, 500, 1000, 1500, 2200 rpm 0 - 5100 array x 4 Nm 0/0/0/0 Temp. breakpoints for 0% and 100% of fan friction torque of FD75 0 - 150 array x 2 °C 80/100 FD13 Torque limit 2, extra torque curves for customer use. Breakpoints for software version 2253: 1000, 1100, 1200, 1400, 1600, 1800, 1900, 2000, 2100, 2200, 2300, 2400 0 - 5100 array x 12 Nm 12 x 5100 FD15 Torque limit 3, extra torque curve for customer use. Breakpoints for software version 2253:
1000, 1100, 1200, 1400, 1600, 1800, 1900, 2000, 2100, 2200, 2300, 2400 rpm 0 - 5100 array x 12 Nm 12 x 5100