SERVICE PROCEDURE MAINTENANCE. DRAINING THE SYSTEM G Before working on the engine or electrical system, dis- connect the negative (ground) battery cable. Tag the cable and controls to warn against starting. G Wear hand and eye protection when draining hot fluids. 1. Run the engine until it reaches operating temperature; then stop the engine 2. Remove the radiator cap as outlined in this section. 3. Remove the crankcase coolant drain plug located on the bot- tom of the coolant inlet (1). 4. Open the radiator drain valve (2). 5. Allow the system to completely drain into a suitable container. Do not let drain outlets plug up during draining. 6. Close the radiator drain valve (2).
Install the crankcase cool- ant drain plug (1). CLEANING THE SYSTEM At 2000 hours clean the cooling system as follows: 1. Drain the system into a suitable container. Refer to “DRAIN- ING THE SYSTEM” on page 194. 2. Drain and clean the reserve tank. 3. Close the radiator and crankcase drains. 4. Fill the system with clean water, refer to “FILLING THE SYS- TEM” on page 195 and add a flushing compound that is com- patible with aluminium. Flush the system in accordance with the instructions furnished with the compound. 5. After flushing, rinsing and completely draining the system. Refill with clean coolant. Refer to“FILLING THE SYSTEM” on page 195. 194 WARNING WARNING