MAINTENANCE Replace Hydraulic Oil Tank Filter --- every 1000 hours WARNING: Hydraulic oil may be hot just ater opera- tion. Be sure to wait for oil to cool before starting work. 5 1. Park the machine on a level surface. 2. Lower the bucket to the ground. W1JB-02-03-006 3. Turn the auto-idle switch off. 8 IMPORTANT: The turbocharger may be damaged if the en- gine is not properly shut down. 4. Run the engine at slow idle speed without load for five minutes. 5. Stop the engine. Remove the key from the key switch. 6. Pull the pilot control shut-off lever to the LOCK position. 7. Leave the machine for a while after stopping operation.

After the oil temperature is cooled, push air bleed valve (8) to bleed air from the hydraulic oil tank. NOTE: There is spring tension under the cover. Hold down the cover when removing last two bolts. 8. Hold down filter cover (2) against light spring load when removing the last two bolts (1). Remove filter cover (2). 2 1 M1J1-07-006 9. Remove spring (4), valve (5) and element (6). 3 4 10. Discard element (6) and O-ring (3). 11. Install a new element (6), valve (5) and spring (4). 5 12. Install cover (2) with new O-ring (3). 13. Install and tighten bolts (1) to 50 N•m (5.1 kgf•m, 37 lbf• ft). 6 14.

After replacing the filter element, bleed air from the pump and check the oil level in the hydraulic oil tank. (Refer to the Bleed Air from Hydraulic System in Step 3.) If the machine is operated with air remaining in the hydrau- lic system, damage to the hydraulic pump may result. 15. Replace the element at the regular interval to keep hydraulic oil clean and to extend the life of the hydraulic components. 7 M111-07-040 7-37