Hitachi Construction Machinery — Hitachi Hydraulic Excavator Manual (EN)

OPTIONAL ATTACHMENTS AND DEVICES REPLACE BREAKER CIRCUIT RETURN OIL FILTER WARNING: Hydraulic oil may be hot. Wait for oil to cool before starting work. 10 Cap 1. Park the machine on a level surface. Lower the breaker to the ground. 2. Leave the machine for a while after stopping operation. After the oil temperature is cooled, push air bleed valve (10) to bleed air from the hydraulic oil tank. 3. Loosen drain plug (9) to drain hydraulic oil from filter case (7). M1J1-07-006 4. Remove bolts (1) to remove cover assembly (4). Front 5. Remove element (6). Inspect the element (6) for metal debris to help in early detection of failures. A 6. Install a new element. Cab 7.

Inspect O-rings (2), (3), (5) and (8) for any damage. Replace damaged O-rings. 8. Confirm that O-rings (2) and (3) are securely in the grooves. Install cover assembly (4) so that arrows (A) on the cover point left, as shown in the figure. Breaker-Circuit-Return-Oil Filter 9. Tighten drain plug (9). Tightening Torque: 44 N•m (4.5 kgf•m, 32.5 lbf•ft) M111-05-009 10. Tighten bolts (1). Tightening Torque: 127 to 147 N•m (13 to 15 kgf•m, 94 to 108 lbf•ft) 1 2 (A810135) 3 (A810095) 4 5 6 (4357445) 7 8 (954493) 9 M111-05-011 13-11