OPERATOR'S STATION ATTACHMENT SELECTION (Only Machines Equipped with Optional Parts) IMPORTANT: Select the attachments from the work mode screen. In order to display the work mode screen, push key F1 after basic screen displays, or select from main menu. Selecting an Attachment by Using Key F1 1. When the basic screen displays, push key F1 and display the work mode screen. Key F1 Basic Screen 2. Push a key located under an attachment mark to be used in order to select the attachment. M1J1-01-002 (In the right example, Breaker 1 is selected.) NOTE: When selecting Digging, return to the basic screen. 3.
On the attachment specification screen, confirm if speci- fication of the installed attachment agrees with that dis- played on the screen. NOTE: When pushing the back key, return to the previous screen. Digging 4. Push the determination key, and the basic screen dis- plays. Back Key Work Mode Screen Select Breaker 1 T1J7-02-01-002E Breaker 1 Maximum Pump Flow Rate 260 L/min Maximum Engine Speed Valve Selector Accumulator 1700 min -1 2-Speed Selector OFF 2ndary Hydraulic Relief Selector 1 2 3 4 5 6 7 8 9 0 F1 F2 F3 F4 Attachment Specification Screen Determination key T1JB-05-02-002E 1-22