Hitachi Construction Machinery — Unit Injector Setting

OPERATIONAL PERFORMANCE TEST / Adjustment UNIT INJECTOR SETTING Summary: 1. After the unit injector is replaced, input the set value of each unit by using a measuring tool (minidiag 2) Preparation: 1. Install cable (2) to minidiag 2 (1). 2. Remove cover (3) on the right side in cab. Install cable (2) to the inside connector. Then, minidiag 2 (1) is turned ON. Measurement: 1. With the key switch OFF, operate minidiag 2 (1). (As for the procedures, refer to the next page.) 2. Input the set value (set No.) of each unit injector (4). T4GB-04-03-005 3 T4GB-04-03-006 4 T4GB-04-03-016 T4-6-8 1 2