OPERATIONAL PERFORMANCE TEST / Engine Test Operating Procedures 1. When minidiag 2 is installed to the machine, the following display is selected. Push and select 2. Push OK. 6. Push and select 03. Push OK. T4GB-04-03-012 7. When the key switch is turned to the START po- sition on the following screen, the engine runs at cranking speed. Then, data is read by minidiag 2. Keep the key switch in the START position until the engine cranking stops. T4GB-04-03-007 2. Select 1 and push OK. T4GB-04-03-008 3. This screen shows search in progress. T4GB-04-03-013 8. The starter stops and the result screen is dis- played. T4GB-04-03-009 4. Select 1 and push OK. T4GB-04-03-014 9.
Push , and select the objective cylinder. The result is displayed on the screen. T4GB-04-03-010 5. Push and select 3. Push OK. T4GB-04-03-015 When finishing, push « . When selecting the cylinder, push , . T4GB-04-03-011 T4-3-5 Cylinder No. and Result The result is dis- played. This is OK. The result is dis- played. This is OK.