Doosan GC20SC-5 — DOOSAN GC20SC-5 Lift Truck Operation & Maintenance Manual PDF (EN)

Operation Section Refueling Only trained, authorized personnel should fill or exchange LP-Gas tanks. Personnel engaged in filling of LP-Gas containers should wear protective clothing such as face shield, long sleeves and gauntlet gloves. Do not refuel or store LP-Gas powered lift trucks near any underground entrance, elevator shafts or any other place where LP-Gas could collect in a pocket causing a potentially dangerous condition. Examine all LP-Gas containers before filling and again before reuse, for damage to various valves, liquid gauge, fittings and hand valve wheels. All defective or damaged LP-Gas containers must be removed from service.

Explosive fumes may be present during refueling. Do not smoke in refueling areas. Lift truck should be refueled only at designated safe locations. Safe outdoor locations are preferable to indoor locations. Stop the engine and get off the lift truck during refueling. The careless handling of LP-Gas containers can result in a serious accident. Use extreme care when transporting containers to prevent damage to them. Changing LP-Gas Tanks W ARN I N G 1. Park the lift truck on level ground, with the parking brake applied, the transmission in NEUTRAL, the forks lowered and the engine running at low idle. 2. Close the fuel shutoff valve at the LP-Gas tank.

Run the engine until it stops, then turn off the ignition switch. 3. Disconnect the fuel supply line. 4. Loosen the retaining clamps and remove the tank. 5. Check the mounting to be sure the locating pin (dowel) is not missing or broken. NOTICE If the locating pin (dowel) is missing or broken, be sure the pin is replaced. 46