Starter Test 1. Measure holder and field coil brush lengths. Minimum brush length is 7.70 mm (0.303 in.) . Replace brush holder or field coil if brush length is below minimum. Field Coil Brush NOTE: Test brush holder using an ohmmeter or test light. 2. Test brush holder: Touch one probe of tester to negative brush holder and other probe to field brush holder. If there is continuity, replace the brush holder. 1 3. Inspect springs for wear or damage. Replace if necessary. Field Coil Housing Spring (4) Negative Brush Holder M82235 IMPORTANT: Do not clean armature with solvent. Solvent can damage insulation on windings. Use only mineral spirits and a brush. 6. Inspect armature.
Look for signs of dragging against pole shoes. 7. Inspect commutator. Look for roughness, burned bars, or any material which might cause short circuits between bars. If necessary, clean and touch up with 400 sandpaper. NEVER use emery cloth. Clean all dust from armature when finished. Field Brush Holder Brush Length NOTE: Test field coil using an ohmmeter or test light. M82234 4. Test for grounded field winding: Touch one probe of tester to field coil brush and other probe to field coil housing. Be sure the brush lead is not touching the frame. If there is continuity, the coil is grounded and the field coil housing assembly must be replaced. NOTE:
Test armature windings using an ohmmeter or test light. 8. Test for grounded windings: Touch probes on one commutator bar and armature shaft. Armature windings are connected in series, so only one commutator bar needs to be checked. 5. Test for open field coil: Touch one probe of tester to each field coil brush. If there is no continuity, the field coil is open and the field coil housing assembly must be replaced. 4/7/95 1-115 AllTractorManuals.com