Starter IMPORTANT: Do not clean armature with solvent. Solvent can damage insulation on windings. Use only mineral spirits and a brush. NOTE: A short circuit most often occurs because of copper dust or filings between two commutator segments. 11.If test indicates short circuited windings, clean the commutator of dust and filings. Check the armature again. If the test still indicates a short circuit, replace the armature. 6. Inspect armature. Look for signs of dragging against pole shoes. 7. Inspect commutator. Look for roughness, burned bars, or any material which might cause short circuits between bars. If necessary, clean and touch up with 400 sandpaper. NEVER use emery cloth.
Clean all dust from armature when finished. 1 Hacksaw Blade Armature NOTE: Test armature windings using an ohmmeter or test light. 8. Test for grounded windings: Touch probes on one commutator bar and armature shaft. Armature windings are connected in series, so only one commutator bar needs to be checked. Growler M82125A 12.Inspect armature cover and housing bearings for wear or damage. Replace if necessary. If test shows continuity, a winding is grounded and the armature must be replaced. 9. Test for open circuited windings: To replace bearings: Touch probes on two different commutator bars. If test shows no continuity, there is an open circuit and the armature must be replaced.
Bearings are press fit. Remove bearings using a knife-edge puller set. IMPORTANT: Install both bearings with sealed side toward armature. Commutator Bars Install new housing bearing tight against shoulder of shaft using a piece of pipe. Install new rear cover bearing tight against shoulder of shaft using a driver set. Rear Cover Bearing Housing Bearing Armature Shaft M82236 10.Test for short circuited windings using a growler. Put armature in a growler and hold a hacksaw blade above each slot while slowly rotating armature. If coil is shorted, the blade will vibrate on the slot. M82237 1-118 4/7/95 AllTractorManuals.com