John Deere Series 220 Diesel Engines — Starter

Starter STARTER SOLENOID - NIPPONDENSO 1.0 kW Disassembly/Inspection 1. Disconnect field lead. 2. Remove three screws and clip. 3. Remove cover and gasket. 1 Field Lead Clip Assembly Assembly is done in the reverse order of disassembly. Screw (3) M82244 4. Remove plunger. NOTE: The assembly sequence of the left and right terminals is similar. Be sure solenoid terminal lead is installed between terminal bolt and contact plate. Also, be sure smaller contact plate is on the left side. 5. Disassemble terminals. Remove parts from each terminal in order shown. 6. Inspect copper washer and contact plates for excessive burning or pitting. Clean burnt areas to improve electrical contact.

Replace contacts or plunger if necessary. The solenoid is not serviceable. If defective, replace solenoid housing assembly. Contact Plates Plunger Spring Copper Washer M82245 4/7/95 1-121 AllTractorManuals.com Terminal Bolt Nut Washer Contact Plate O-Ring Insulator M36771 M36771 Solenoid Terminal Lead Terminal Bolt Small Contact Plate M36771 Small Contact Plate M36771