John Deere Series 220 Diesel Engines — Alternator

Alternator VOLTAGE REGULATOR - NIPPONDENSO 40A Replacement 1. Remove nut and insulator. 2. Remove three screws and cover. 1 4. Remove four screws and straighten stator wire leads. 5. Remove rectifier. 3. Remove two screws, brush holder and cover. 4. Remove three screws. Replace voltage regulator. Voltage Regulator Long Screw (2) 6. Remove two nuts, two screws and end frame assembly. Short Screw 7. Press rotor shaft from end frame. 8. Remove spring washer. Brush Holder and Cover M52472 Installation is done in the reverse order of removal. IMPORTANT: Make sure to install short screw at location shown. Longer screw will contact frame and cause damage to the charging system.

ALTERNATOR - NIPPONDENSO 40A Disassembly 1. Remove voltage regulator. (See VOLTAGE REGULATOR - REPLACEMENT in this group.) 9. Remove four screws and retainer. 2. Remove nut. NOTE: Front bearing is press fit in front frame. Remove bearing only if replacement is necessary. 3. Remove sheave using a puller set. 1-128 4/7/95 AllTractorManuals.com Nut 69 N•m (51 lb Sheave M52469 Nut 69 N•m (51 lb -ft) Sheave M52469 Cover Nut a Insula M52470 Nut a Insula nd tor Rect Wire (4) M5247 Rect ifier 1 Stator Lead Wire (4) M52470 M5247 1 Spring Washer End Fra Rotor Assembl Shaft M52473 End Fra Assembl me y M52473