Checks, Tests and Adjustments Results: If nozzle chatter or spray pattern does not meet specifications, disassemble injection nozzle and inspect nozzle assembly for contamination. Inspect valve seating surface. Replace nozzle assembly if necessary. If there is excessive difference in spray angle or injection angle, incomplete atomization or sluggish starting/stopping of injection, disassemble injection nozzle and inspect nozzle assembly for contamination. Replace nozzle assembly if necessary. 1 THERMOSTAT OPENING TEST Reason: Specifications: To determine opening temperature of thermostat. Begin Opening. . . . . . . . . . . . . 71° C (160° F) Fully Open . . . . . . . . . . . . . . . .
85° C (184° F) Minimum Lift Height . . . . . .8 mm (0.310 in.) Equipment: Thermometer Glass Container Heating Unit Results: If thermostat does not open according to specifications, replace. Procedure: If closing action is not smooth and slow, replace thermostat. COOLANT TEMPERATURE SENSOR TEST Reason: To determine operating temperature of sensor. Equipment: 1. Suspend thermostat and a thermometer in a container of water. Thermometer Glass Container 2. Heat and stir the water. Observe opening action of thermometer and compare temperatures with specifications. Heating Unit Ohmmeter 3. Remove thermostat and observe its closing action as it cools.
1-144 4/7/95 AllTractorManuals.com Thermometer Thermo M82 stat M82 122A Thermo stat CAUTION DO NOT allow thermostat or thermometer to rest against the side or bottom of glass container when heating water. Either may rupture if overheated.