John Deere Series 220 Diesel Engines — Operational Tests

Operational Tests Specifications - 15 EX: 6. Spray soap solution over all connections from air cleaner to intake manifold or turbocharger, if equipped, and check for leaks. Idle Speed Fast . . . . . . . . . . . . . . . . . . . 2425 ± 25 rpm Slow . . . . . . . . . . . . . . . . . . . 800 ± 25 rpm Engine Oil Pressure . . . . . . . . . 117 - 345 kPa . . . . . . . . . . . . . . . . . . . . . . . . . . . (17 - 50 psi) IMPORTANT: When reinstalling starting aid nozzle, position arrow on nozzle pointing against intake air flow. Specifications - 3009 OEM: Slow Idle. . . . . . . . . . . . . . . . . . . . . . 1300 rpm Engine Oil Pressure . . . . . . 147 kPa (21 psi) 1 Results:

If oil pressure is not within specifications, inspect oil pressure regulating valve parts for wear or damage. Add or remove shims as necessary. (See Lubrication System in this section.) Results: If oil pressure does not increase, see “Engine Has Low Oil Pressure” in Diagnosis group. Find leaks and repair or replace parts as necessary. FUEL SUPPLY PUMP PRESSURE TEST - 3TNA72 (670 CUT, 3009 OEM) AIR INTAKE SYSTEM LEAKAGE TEST Reason: Check for leaks in air intake system. Reason: Equipment: To determine supply pump operating pressure. Air Pressure Regulator Equipment: JT03274 Hose Fitting Procedure: JT01609 Female Quick Coupler 1.

Remove air cleaner restriction indicator/switch, if equipped and install test fitting. JT03115 Gauge w/Male Quick Coupler (0 - 150 psi) 2. Connect air pressure regulator to manifold using hose and fitting from air cleaner. Procedure: 3. Remove air cleaner cover and main filter element. 1. Disconnect supply pump-to-filter hose. 4. Put large plastic bag into and over end of main filter element. Install main filter element and cover. 2. Install Hose Fitting, Coupler and Gauge. 3. Pull fuel shut-off cable out and crank engine using the starter. Do not run starter for more than 10 seconds at a time. Gauge should read more than 29 kPa (4.3 psi) . 5.

Pressurize air intake system between 34 - 69 kPa (5 - 10 psi) . If air intake system cannot be pressurized, turn engine slightly to close valves. 4/7/95 1-155 AllTractorManuals.com M82124 M82124