The Charles Machine Works, Inc. RT45-Tier4 — Saw

RT45 Operator’s Manual Service - 157 10 Hour p Check Plow Vibrator Oil Level Hot parts may cause burns. Do not touch until cool. Check plow vibrator oil level every 10 hours. With vibrator horizontal, oil should be halfway up sight glass (2). Add MPL as needed at fill (1). Saw Clean Saw Clean saw every 10 hours. Wash bolts and mounting blocks with high-pressure water. Check Saw Mounting Bolts Tighten to 200 ft•lb (271 N•m). olts lts every 10 hours.